Home Products Arthroscopic Implants Labral Suture Passer

Products

Labral Suture Passer
Labral Suture Passer Labral Suture Passer Labral Suture Passer Labral Suture Passer Labral Suture Passer

Labral Suture Passer

Product Tags : labral suture passer
Product Attributes :
  • HP2236 Labral Suture Passer for arthroscopic labral repair procedures.
  • Designed to assist controlled suture passage through labral tissue under arthroscopic visualization.
  • Matching HP2236.1 Labral Suture Passer Needle is shown with a 4.8 x 140 mm specification.
  • The HP2236 passer is shown with a long shaft and curved distal working section for controlled access to the repair site.
  • Suitable for trained orthopedic and sports-medicine professionals following the applicable surgical technique and instructions for use.
Product Description

HP2236 Labral Suture Passer

The HP2236 Labral Suture Passer is an arthroscopic instrument designed to assist suture passage during labral repair procedures. It is intended for controlled handling of repair sutures under direct arthroscopic visualization and should be used by trained orthopedic or sports-medicine professionals according to the current surgical technique and instructions for use.

The supplied product image shows a long-shaft passer with a handle and a curved distal working section. This configuration is intended to support access and controlled positioning during arthroscopic labral repair. The final portal, cannula and approach selection must be determined by the responsible surgeon according to the patient anatomy, repair location and validated technique.

The product image also shows the matching HP2236.1 Labral Suture Passer Needle. Both the HP2236 passer and the HP2236.1 needle are labeled 4.8 x 140 mm in the supplied material. The needle may be a dedicated working component or a separately supplied replacement item; the exact package configuration must be confirmed in the current product label and technical documentation.

During an arthroscopic labral repair workflow, a suture passer may be used to position or pass a repair suture through the target labral tissue before the suture is secured using the selected repair construct. The passer itself is not a suture anchor, implant or fixation device. It should not be described as providing fixation strength or healing outcomes independently of the complete surgical construct.

Labral repair instruments are used in procedures involving abnormal or torn labral tissue. Depending on the joint and the repair plan, labral repair may involve the shoulder or hip. The supplied image does not specify a joint-specific version, so the product page should use the broader term arthroscopic labral repair unless the manufacturer confirms a dedicated shoulder or hip indication.

Product components shown:

  • HP2236 - Labral Suture Passer, 4.8 x 140 mm shown.
  • HP2236.1 - Labral Suture Passer Needle, 4.8 x 140 mm shown.

Clinical and technical information boundary: The supplied image does not confirm the material grade, needle tip design, suture compatibility, working-jaw mechanism, handle actuation method, cannula compatibility, reusable or disposable status, sterilization method, sterile status, packaging, shelf life, regulatory certificates or joint-specific indications. These details should be added only after confirmation from the current technical file, product label or instructions for use.

Frequently Asked Questions

1. What is the HP2236 Labral Suture Passer used for?

HP2236 is an arthroscopic instrument designed to assist controlled suture passage during labral repair procedures. The passer should be used under direct arthroscopic visualization by trained healthcare professionals.

2. What is the difference between HP2236 and HP2236.1?

HP2236 is identified as the Labral Suture Passer. HP2236.1 is identified as the matching Labral Suture Passer Needle. The supplied image shows a 4.8 x 140 mm specification for both components.

3. Is the 4.8 x 140 mm dimension confirmed?

Yes. The supplied product image labels both the HP2236 passer and the HP2236.1 passer needle as 4.8 x 140 mm.

4. Can HP2236 be used for shoulder labral repair?

The product is identified as a Labral Suture Passer and is relevant to arthroscopic labral repair. A shoulder-specific indication, portal compatibility and applicable technique must be confirmed in the manufacturer’s current documentation before making a joint-specific claim.

5. Can HP2236 be used for hip labral repair?

The supplied image does not specify a joint-specific version. Use for hip labral repair should be stated only if supported by the current instructions for use and validated surgical technique.

6. Is HP2236 supplied sterile?

Sterile status and sterilization method are not shown in the supplied image. Do not describe HP2236 as sterile or ready for implantation unless the product label and technical documentation confirm it.

7. Is HP2236 a labral implant or suture anchor?

No. HP2236 is identified as a Labral Suture Passer, which is an instrument used to assist suture passage. It should not be presented as an implant, anchor or independent fixation device.

Online Inquiry